ThermalBuck
Brand: Thermal Buck™The ThermalBuck is an innovative high-performance window and door buck designed to extend the building’s insulation layer right to the rough opening. Made from a high-density, closed-cell foam core with a waterproof coating, it eliminates thermal bridging, improves energy efficiency, and protects against moisture damage.
ThermalBuck is lightweight, easy to cut, and installs quickly, making it a practical solution for high-performance construction. It’s compatible with all types of cladding and integrates seamlessly with weather barriers and flashing systems.
- Extends the mounting point of windows & doors to meet the exterior insulation and/or rainscreen plane.
- Acts as a flashing agent, creates a complete water & air barrier when mounted with recommended sealants.
- Insulates the mounting point of windows & doors 4x more than wood window bucks.
- Limits thermal bridging, with an R-value range of 4.4 to 17.6.
- Prevents condensation, reduced thermal bridging means less moisture, mold and mildew.
- Handles shear and wind loads up to 70 lbs per linear inch.
- Sustains hurricane force winds with minimal permanent compression (compressive strength of 52 psi).
- Allows structural attachment of windows & doors (must penetrate structure min. 1-1/4″).
- 1/16″ integrated sill pan for good drainage.
- Dimensionally stable and elastic. ThermalBuck won’t warp, shrink, or expand like wood window bucks.
- Energy-efficient, reduces the amount of natural resources needed to heat and cool year-round.
- Improves Indoor Air Quality by preventing condensation.
- Helps maintain the long-term operating ease of windows & doors.
- Lightweight, flexible, durable and strong, ThermalBuck is easy to work with and install with one person.
- Simplifies the installation of windows & doors.
- ThermalBuck outperforms wood window bucks, and is easier to flash properly, window after window
Displaying prices & availability for Ohio, United States 43201 in CAD. Change location.
| THERMALBUCK:THERMALBUCK Thermal Tight (4x8 sheets) 1.5" |
Specifications
Brand
R-Value at 75° F
- 1" = 4.4
- 1.5" = 6.6
- 2" = 8.8
- 2.5" = 11
- 3" = 13.2
- 3.5" = 15.4
- 4" = 17.6
R-Value at 40° F
- 1" = 4.8
- 1.5" = 7.2
- 2" = 9.6
- 2.5" = 12
- 3" = 14.4
- 3.5" = 16.8
- 4" = 19.2
R-Value at 25° F
- 1" = 5
- 1.5" = 7.5
- 2" = 10
- 2.5" = 12.5
- 3" = 15
- 3.5" = 17.5
- 4" = 20
Compressive Strength (ASTM C165)
- @ 10 % Deformation
- 52.4 psi
Design Pressure (ASTM E330/E330M)
- +203.01 psf
- -203.01 psf
- < 0.5 mm (0.02")
- < 0.8 mm (0.03")
Structural Pressure (ASTM E330/E330M)
- ± 300.76 psf
- < 0.3 mm (< 0.01")
Water Penetration (ASTM E547)
- 9.19 psf
- Pass
Air Infiltration (ASTM E283)
- 1.57 psf
- 6.24 psf
- < 0.01 cfm/ft²
Burn Test (ASTM E84)
- Class A or 1 Fire Rating
- FS< 25, SD< 450
Composition
- Type XIV EPS with Polyurethane/polyurea Resin Coating - Contains termiticide
Documentation
Installation Guide
Safety Data Sheet
Specifications